Pool Dose Lab

LSI Calculator

Enter pH, water temperature, calcium hardness, alkalinity, CYA and TDS to see whether your water is balanced, corrosive or scale-forming — and the single change that would bring it to 0.

Last reviewed · How we calculate

Test results

Leave at 1,000 if you have not tested it.

Your result

— Balanced

Temperature factor (TF)
—
Calcium factor (CF)
—
Alkalinity factor (AF)
—
TDS constant
—

One change that brings LSI to 0 (pick one, not all):

    LSI = pH + TF + CF + AF − TDS constant. A widely used target is −0.3 to +0.3.

    What this LSI calculator tells you

    The Langelier Saturation Index (LSI) answers one question: will this water dissolve calcium carbonate, or deposit it? At 0 the water is exactly saturated and does neither. Below 0 it is hungry for calcium and will take it from plaster, grout, pebble finishes and, together with low pH, metal parts. Above 0 it has more than it can hold and drops it as scale on tile lines, in heater exchangers and on salt-cell plates. This LSI calculator combines your readings into that single number, shows how much each one contributes, and works out what one change would bring the index to 0.

    How the LSI is calculated

    LSI = pH + TF + CF + AF − TDS constant

    • pH goes in as measured. It has the biggest single effect: 0.1 pH is 0.1 LSI.
    • Temperature factor (TF) comes from a standard table, from 0.0 at 32 °F to 0.7 at 84 °F and 0.9 at 105 °F. The calculator interpolates between table points.
    • Calcium factor (CF) is log₁₀(calcium hardness) − 0.4. Doubling calcium adds only about 0.3.
    • Alkalinity factor (AF) is log₁₀(carbonate alkalinity). Carbonate alkalinity is your total alkalinity minus the part that comes from cyanuric acid, which the calculator estimates from your CYA and pH.
    • TDS constant is 12.1 for total dissolved solids up to 1,000 ppm and 12.2 above that, which covers salt pools.

    The CYA correction matters more than many people expect. At pH 7.5, 40 ppm of cyanuric acid accounts for about 12.5 ppm of a total alkalinity reading. Skip the correction and the LSI comes out too high, so water that is slightly corrosive can look balanced.

    Worked example

    A vinyl pool reads pH 7.2, 78 °F, calcium 150 ppm, TA 60 ppm, CYA 40 ppm, TDS 1,000. Carbonate alkalinity is about 49.5 ppm, so the factors are TF 0.63, CF 1.78 and AF 1.69. The LSI is 7.2 + 0.63 + 1.78 + 1.69 − 12.1 ≈ −0.80: corrosive. To bring it to 0 with one change, pH would have to rise to about 8.04, or calcium to about 956 ppm, or TA to about 326 ppm. Raising pH alone that far is not sensible either, so the practical fix is a combination: TA up to about 80, pH to 7.5 and calcium toward 200 to 250 ppm. The same water marked as a salt pool reads −0.90.

    How temperature alone shifts the LSI (pH 7.5, CH 300, TA 80, CYA 40, TDS 1,000)
    Water temperatureTemperature factorLSI
    50 °F (10 °C)0.26−0.44
    84 °F (29 °C)0.70+0.01
    104 °F (40 °C)0.89+0.20

    Using the result

    Treat −0.3 to +0.3 as the working band, a widely used guideline. Plaster pools often aim for −0.3 to 0 in summer and slightly higher in winter, because cold water reads lower. Salt pools and heated pools benefit from staying at or a little below 0, since the cell plates and heater exchanger run hotter than the pool and scale there first.

    1. Fix the easiest reading first. pH is quick to change; calcium only goes up with calcium chloride and only down by draining.
    2. Keep alkalinity where it keeps pH steady (often 60 to 90 ppm), then fine-tune with pH and calcium.
    3. Recalculate after every change, and again when the season changes water temperature.

    The LSI says nothing about sanitation. Water can be perfectly balanced and still unsafe if free chlorine is too low for its CYA.

    Common mistakes

    • Using total alkalinity without the CYA correction, which overstates the LSI.
    • Calculating once in summer and never again. A drop from 84 °F to 50 °F lowers the index by about 0.44.
    • Chasing LSI with pH alone. Pushing pH to 8 to fix a corrosive reading hurts chlorine performance; raise calcium or alkalinity instead.

    To get the doses for each change, use the calcium hardness calculator, the pool pH calculator or the full pool chemical calculator, which shows the LSI before and after its plan.

    Questions people ask

    What is a good LSI for a pool?

    A widely used target is −0.3 to +0.3, with 0 meaning the water neither dissolves nor deposits calcium carbonate. Below −0.3 the water tends to etch plaster; above +0.3 it tends to form scale.

    How do I raise the LSI?

    Raise pH, calcium hardness or alkalinity, or the water temperature. pH has the most direct effect: raising pH by 0.1 raises LSI by about 0.1, while doubling calcium hardness raises it by only about 0.3.

    Why does the LSI calculator ask for cyanuric acid?

    Part of a total alkalinity reading comes from cyanuric acid, not carbonate, and only carbonate alkalinity counts toward calcium scale. At pH 7.5, 40 ppm CYA accounts for about 12.5 ppm of the alkalinity reading.

    Does a salt pool change the LSI?

    Yes, slightly. Salt pools have total dissolved solids well above 1,000 ppm, so the TDS constant rises from 12.1 to 12.2 and the LSI drops by 0.1. Salt cells also run hot, which raises scaling at the cell itself.

    Does temperature affect the LSI?

    Yes. Warmer water is more scale-forming. The same water at 50 °F reads about 0.44 lower than at 84 °F, so a pool balanced in summer can turn corrosive in winter.

    Sources and references